Sunday, September 14, 2014

This document will help us to focus on safety issues in the manipulation, room warmer storage and u


Compressed room warmer air can be in the form of material contained room warmer in the tank and be directed to the factory for production purposes or contained in compressed gas cylinders with oxygen 1 Rating 2 Rating acetylene pressure reducing valve with pressure relief valves 3. This comprehensive 4 Conductors front oxygen (air) Conductors acetylene gas 5 6 7 Welding Welding room warmer Welding Company 8 9 10 Details welding flame welding and cutting
This document will help us to focus on safety issues in the manipulation, room warmer storage and use of compressed room warmer air in the welding field. Obvious danger room warmer and most of the first compressed air and gas in the bottle is squeezed under pressure, some average high pressure up to 2,200 pounds room warmer / square inch. An average damaged or broken valves can cause sudden gas leak make average n roll and become damaged rocket with a destructive power enough to penetrate a brick wall. Other hazards are gases contained in the bottle, there are hundreds of gases and mixtures used in pneumatic cylinders. gases such as acetylene, propane, butane and hydrogen is highly flammable and potentially explosive. Oxygen itself is not flammable, but when met fire it will make the fire bigger boom. Gases such as ammonia and chlorine is very toxic, just a small amount of leakage is also asking people to evacuate the workplace. Argon, nitrogen and helium are inert gases, but it is dangerous because it took place in the air that people suffocate for lack of air to breathe. This document includes the following contents: Keep proper scuba scuba Move Manipulating average safety room warmer when welding (welding) Save Gas Acetylene 1 Store scuba how to be true how? Observe and identify true or false?
Signs above the scuba like? There is not enough information? The compressed air can be kept reasonable? The pneumatic cylinders are placed standing or lying? What would happen if the compressed room warmer air collision with each other? What to do to avoid lodging of compressed air? The compressed air can be clearly labeled and painted the appropriate color code? The various pneumatic cylinders should be stored close together or as far apart?
Arrow 1: Worksheet "compressed air storage site" tells us that the compressed air that is stored in this area, but it does not indicate the potential risks that workers need to know. There should be more information to indicate hazards may exist. For example, adding the warning room warmer "Danger! Compressor, No smoking ..." Arrow 2: Binh oxygen scuba placed next to the other is not safe, put the average distance away from the average oxygen flammable compressed gas (such as acetylene) at least 20 feet (6 meters). Oxygen is not spontaneous combustion, but it provides oxygen to make fire faster than other substances (especially oils, greases ...) and create ignition sources in combination with the compounds such as gasoline into combustible mixture. Arrow 3: The average fall can park at any time. Injury or death that may occur when the gas tank nenkhi it falls into other objects collide and rupture. At that point the compressed air as a gas over massive rocket ejected. Compressed air tank is full or empty though (used up) must be wired to a fixed column, avoid falls park. Arrow 4: Lid van on the average no. Valve cover is a safety device to prevent the valve from being damaged during a fall park. The lid must remain closed except when the valve is used. Arrow 5: Note the compressed air in the region "Empty" does not mean that the average empty. room warmer Empty cylinders must be marked with the word "Empty" or "MT" on the comment itself. Proper design where compressed air:
The sign above the slot average was amended to address potential threats to the region did not warn workers not smoke or use fire in the storage area average. The oxygen tanks were taken out and placed the area is 20 feet. Catenary system to prevent room warmer the lodging of compressed air. All compressed air tanks are full the valve cover the range Gas Tank "Empty" is the signboard clearly marked.
Danger warning stickers. Keep oxygen at least 20 feet away (# 6 meters) compared room warmer with other pneumatic cylinders. Avoid self parking pneumatic cylinders and valves Always close the lid labeled empty comment. 2 Move the compressed room warmer air: Observe and identify true or false? This hand pallet truck with the right kind of used to transport compressed air? In addition to using hand pallet truck safety is no other way to move the scuba? Doing nothing to prevent the compressed air out of hand pallet truck dropped? What will happen when scuba hand pallet truck fell out? You can use any way to protect the valve? This worker's hands are oily and he was holding open the valve, no danger room warmer that will happen?
Arrow 1: This hand pallet truck should not use compressed air transportation, when manipulated or transported must ensure not falling average damage, this hand pallet room warmer truck backs Flat titles only appropriate to move the boxes, crates Flat feet or objects. Arrow 2: Note that average should not be fixed with belts to avoid falling beans, hand pallet truck

No comments: